01

Testing of elements for marine use according to IMO FTP Code (International Maritime Organization, International Code for the Application of Fire Test Procedures). Amendments to the International Convention for the Safety of Life at Sea (SOLAS).

Tipo: Test standard

Standard: 2010 IMO-FTP CODE, SOLAS Chapter II-2

Clienti:

IMO, the International Maritime Organization, is the United Nationsspecialized agency for ship safety.
FIRE TESTS FOR NAVAL ELEMENTS
With the FTPcode - Fire Testing Procedures- he indicated the stardards for the testing of naval elements. We normally test bulkheads and components in class B15, B30 or A60in accredited laboratories. The test laboratory has a furnace that is capable of following a heating curve established by ISO 834. If the element to be tested is to be installed on a bulkhead, the element inserted in the bulkhead built in accordance with the desired class is tested. "B-0" 0 min insulation 30 min integrity "B-15" 15 min insulation 30 min integrity "A-0" 0 min insulation 60 min integrity "A-15" 15 min insulation 60 min integrity “A-30” 30 min insulation 60 min integrity “A-60” 60 min insulation 60 min integrity.
THE CHEMOLLI FIRE CONTRIBUTION
When it comes to testing, we provide our experience and our KNOW-HOW. Having always done this type of activity, as specialists, we offer you complete advice during all the laboratory experimentation phases, from design to documentation of results. THE METHOD Listening is the most important phase of our interaction: we want you to develop a product that is the sum of your identity and your needs. First of all, we'll try to understand your real needs, the channels and the markets you want to measure yourself on. Then we will show you how the testing and certification process takes place: we need to deal with you, to fully grasp your point of view. Then, we concert a proposal that respects - compatibly with the required performances - your product lines, your production lines and, as far as possible, the potential economies of scale by using products and methodologies already consolidated in your company. EMPATHY Beyond the opportunities, which we will show you, we will then advise you what we would do, in your shoes. We advise with our experience on what, how and where to test. In which laboratory should you test? In the one that best suits your needs! THE PROJECT Once the key is turned, we prepare a project that is exhaustive of all the details. Which materials and components to use, an important part of our dialogue on which we can best advise you. In addition to this, a cost sheet and a forecast of weights, to allow you to check if your goals will be achieved. Using the best practices in the sector, we are convinced of this. ATYPICAL CONSULTANTS: WE TAKE CARE OF THE TESTING ACTIVITY A consultant gives advice, then lets the client put it into practice. We are not like this: we take off tie and put on our work clothes when needed. Once the production of the samples has been launched, we are present during the gluing of the doors, we offer support during processing and hardware installation, we proceed with our technicians to install the samples in the laboratory and we are physically present at the test. We manage the post-test documentation review phase, we illustrate the documentation and remain available for all issues related to results management.
IN DEPTH
01

Testing of elements for marine use according to IMO FTP Code (International Maritime Organization, International Code for the Application of Fire Test Procedures). Amendments to the International Convention for the Safety of Life at Sea (SOLAS).

Tipo: Test standard

Standard: 2010 IMO-FTP CODE, SOLAS Chapter II-2

Clienti:

IMO, the International Maritime Organization, is the United Nationsspecialized agency for ship safety.
FIRE TESTS FOR NAVAL ELEMENTS
With the FTPcode - Fire Testing Procedures- he indicated the stardards for the testing of naval elements. We normally test bulkheads and components in class B15, B30 or A60in accredited laboratories. The test laboratory has a furnace that is capable of following a heating curve established by ISO 834. If the element to be tested is to be installed on a bulkhead, the element inserted in the bulkhead built in accordance with the desired class is tested. "B-0" 0 min insulation 30 min integrity "B-15" 15 min insulation 30 min integrity "A-0" 0 min insulation 60 min integrity "A-15" 15 min insulation 60 min integrity “A-30” 30 min insulation 60 min integrity “A-60” 60 min insulation 60 min integrity.
THE CHEMOLLI FIRE CONTRIBUTION
When it comes to testing, we provide our experience and our KNOW-HOW. Having always done this type of activity, as specialists, we offer you complete advice during all the laboratory experimentation phases, from design to documentation of results. THE METHOD Listening is the most important phase of our interaction: we want you to develop a product that is the sum of your identity and your needs. First of all, we'll try to understand your real needs, the channels and the markets you want to measure yourself on. Then we will show you how the testing and certification process takes place: we need to deal with you, to fully grasp your point of view. Then, we concert a proposal that respects - compatibly with the required performances - your product lines, your production lines and, as far as possible, the potential economies of scale by using products and methodologies already consolidated in your company. EMPATHY Beyond the opportunities, which we will show you, we will then advise you what we would do, in your shoes. We advise with our experience on what, how and where to test. In which laboratory should you test? In the one that best suits your needs! THE PROJECT Once the key is turned, we prepare a project that is exhaustive of all the details. Which materials and components to use, an important part of our dialogue on which we can best advise you. In addition to this, a cost sheet and a forecast of weights, to allow you to check if your goals will be achieved. Using the best practices in the sector, we are convinced of this. ATYPICAL CONSULTANTS: WE TAKE CARE OF THE TESTING ACTIVITY A consultant gives advice, then lets the client put it into practice. We are not like this: we take off tie and put on our work clothes when needed. Once the production of the samples has been launched, we are present during the gluing of the doors, we offer support during processing and hardware installation, we proceed with our technicians to install the samples in the laboratory and we are physically present at the test. We manage the post-test documentation review phase, we illustrate the documentation and remain available for all issues related to results management.
IN DEPTH

Ask for information about testing
Naval IMO-FTP code Fire resistance

Ask for information about testing
Naval IMO-FTP code Fire resistance