products and solutions

Doors

We have a wide range of tested fire doors with different performances, from 30 to 180 minutes and from 28 to 52 dB. Tests were made at main testing bodies such as Rina, CSI, Z-Lab, Lapi, Applus, IFT Rosenheim, Exova. Our customers, manufacturers of doors, may obtain a construction license to manufacture them in cascading according to EN16034 sending an application enquiry to info@chemollifire.com.
Chemolli Fire Research

X355 - EI 30 1A thk. 44

Chemolli Fire Systems single leaf hinged door, X355 family, with wooden leaf and frame, fire resistance classification EI1 30 REI 30 following the EN 1634-1:2014 standards. The door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards with sound performance from 28 dB to 39 dB.

X351 - EI 30 2A thk. 44

Chemolli Fire Systems single leaf hinged door, X351 family, with wooden leaf and frame, fire resistance classification EI1 30 REI 30 following the EN 1634-1:2014 standards.

X411 - EI 30 1A thk. 48

Chemolli Fire Systems single leaf hinged door, X411 family, with wooden leaf and frame, fire resistance classification EI1 30 REI 30 following the EN 13501-2:2007 + A1:2009 standards.

X171 - EI 30 1A thk. 50

Chemolli Fire Systems single leaf hinged door, X171 family, with wooden leaf and frame, fire resistance classification EI1 30 REI 30 following the EN 13501-2:2007 + A1:2009 standards.

X277 - EI 30 1A Rasomuro Push thk. 50

Chemolli Fire Systems single leaf hinged door, X277 family, with wooden leaf and frame, fire resistance classification EI1 30 REI 30 or EI1 45 REI 45 following the EN 13501-2:2007 + A1:2009 standards. The door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards with 39.3 dB sound performance.

X429 - EI 30 1A Rasomuro T thk. 50

Chemolli Fire Systems single leaf hinged door, X429 family, with wooden leaf and frame, fire resistance classification EI 30 following the EN 13501-2:2007 + A1:2009 standards.

X240 - EI 45 1A Pierced thk. 70

Chemolli Fire Systems single leaf hinged door, X240 family, with wooden leaf and frame, fire resistance classification EI1 45 REI 45 following the EN 13501-2:2007 + A1:2009 standards.

X241 - EI 60 1A Pierced Door thk. 102

Chemolli Fire Systems single leaf hinged door, X241 family, with wooden leaf and frame, fire resistance classification EI1 60 REI 60 following the EN 13501-2:2007 + A1:2009 standards.

X073 - EI 60 1A 60 Swing Door thk. 60

Chemolli Fire System single leaf swing door, X073 family, with wooden leaf and frame, fire resistance classification EI1 60, or EI1 30, following the EN 13501-2:2007 + A1:2009 standards.

X361 - EI 60 2A 60 Swomg Door thk. 70

Chemolli Fire System double leaf swing door, X361 family, with wooden leaf and frame, fire resistance classification EI1 60 REI 60, following the EN 13501-2:2016 standards.

X371 - EI 60 1A sp. 60

Chemolli Fire System single leaf swing door, X371 family, with wooden leaf and frame, fire resistance classification EI1 60 following the EN 13501-2:2007 + A1:2009 standards. The door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards up to 45 dB sound performance.

X412 - EI 60 1A Filo S/T thk. 60

Chemolli Fire Systems single leaf hinged door, X412 family, with wooden leaf and frame, fire resistance classification EI1 60 REI 60 following the EN 13501-2:2007 + A1:2009 standards.

X285 - EI 60 1A Filo S/T thk. 70

Chemolli Fire Systems single leaf hinged door, X285 family, with wooden leaf and frame, fire resistance classification EI1 60 REI 60 following the EN 13501-2:2007 + A1:2009 standards. The door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards with 50 dB sound performance.

X313 - EI 60 2A Filo S/T thk. 80

Chemolli Fire System door, X313 family, double wooden leaf with wooden leaf and frame, fire resistance classification EI1 60 following the EN 13501-2:2007 + A1:2009 standards.

X416 - EI 60 1A Boiserie thk. 67

Chemolli Fire Systems single leaf hinged door, X416 family, with wooden leaf and frame, fire resistance classification EI1 60 REI 60 following the EN 13501-2:2007 + A1:2009 standards. The door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards with sound performance (Rw) from 35,1 up to 44 dB.

X399 - EI 60 2A Boiserie thk. 66

Chemolli Fire System single leaf swing door, X399 family, double wooden leaf with wooden leaf and frame, fire resistance classification EI1 60 REI 60 following the EN 13501-2:2007 + A1:2009 standards.

X318 - EI 120 1A Filo S/T thk. 100

Chemolli Fire System single leaf hinged door, X318 family, with wooden leaf and frame, fire resistance classification EI1 120 REI 120 following the EN 13501-2:2007 + A1:2009 standards, the door has been tested to sound insulation following UNI EN ISO 10140-2:2010 standards with sound performance from 35,6 dB to 52,1 dB.

 

X387 - EI 120 2A Filo S/T thk. 100

Chemolli Fire System single leaf hinged door, X387 family, double wooden leaf with wooden leaf and frame, fire resistance classification EI1 120 REI 120 following the EN 13501-2:2016 + A1:2009 standards.